1.Merchandise Specification:

Merchandise S1100VG
  Optimum frequency 400H
  Enter frequency Digital setting: .01Hz
  resolution Analog location: greatest frequency ×0.one%
  Manage mode V/F manage
  Vector flux management 1
  Vector flux control two
  CZPTtup torque G modle: .5Hz/one hundred eighty%(Open loop Vector flux control)
  P model: .5Hz/a hundred and twenty%(Open loop Vector flux control)
  Speed adjustment one:two hundred(Open up loop Vector flux control)
  selection
  Velocity stabilization Open up loop Vector flux control:≤±0.five%
  precision
Standard operate Speed stabilization Open up loop Vector flux manage:≤±0.3%
  precision
  Torque response ≤40ms(Open up magnetic flux vector control)
  Overload ability G design: 150% rated recent 60s 180% rated recent 3s
  P design: one hundred thirty% rated recent 60s one hundred fifty% rated existing 3s
  Torque hoist Automatic torque hoist handbook torque hoist .one% to
  thirty.00%
  V/F curve CZPT V/F, Multi-position V/F, and Square V/F
  Speed-up and Straight line or S curve velocity-up and velocity-down
  Speed-down curve modeTwo varieties of pace-up and speed-down
    timeSpeed-up and speed-down time ranges among .0s
    to 3000.0min.
  DC brake DC brake frequency:.00Hz to maximum frequency 
brake time:.0s to 36.0s,and brake existing value: .% to 100.%.
  Jog control Jog frequency variety:.00Hz to fifty.00Hzjog
  velocity-up/velocity-down time: .0s to 3000.0s.
  Simple PLC and MS pace running It can realize a maximum of sixteen segments speed operating
  by means of the built-in PLC or manage terminal.
  Constructed-in PID It is simple to recognize procedure-managed shut loop manage
  program.
  (AVR)Vehicle It can maintain continual output voltage immediately in case 
of adjust of mains voltage.
  voltage regulation
  Torque limit and manage “Shovel” characteristics, the runtime computerized torquelimit, prevent frequent 
more than-present excursion closed loop vectormodel can understand the torque management
Individua-lized perform Peripherals self-detection on It can carry out security detections on the peripherals on power-on, 
including earth and short circuit detections.
electricity-on
Shared DC bus It can realize the operate that multiple inverters share the DC bus.
purpose
JOG essential Programmable essential: Choose the command channel switching/CZPT 
and reverse rotations/jog procedure.
Show LED show The device has the LED keyboard,and recognize parameter 
options,standing monitoring perform.
and
Keyboard Lcd show Optional, / English prompts content material
Operation Parameter Duplicate Keyboard can be copied utilizing the parameters to achive
the rapid replication parameter.

 
 
2.Solution Characteristics:

one.Enhanced Control and Overall performance
two.Switchable Twin Score Procedure Manner:Regular Obligation/Weighty Responsibility
3.Various Functions:(Created-in programmable Logic Controller,PID Handle Selection,Multi speed handle with 16 phase frequency variety)
four.Security of environment(Environment oriented style,Enhanced ecological qualities)

3.Product Show:

4.Speak to Us:

 

S1100vg 220V 380V 415V 3 Phase Input Output VFD 15HP VSD Drive with Tension Control Function

Tags